Mfg Model=CN-20MP
UPC code=654061028482
Furman’s Contractor Series MiniPorts extend the benefits of SmartSequencing to electronics outside of the equipment rack, providing tremendous flexibility to any installation scenario. Units may be daisy-chained and fully controlled via a Furman SmartSequencer, legacy Furman sequencer, third-party sequencers, via the Internet (with BB-RS232 adaptor and SmartSequencer), and/or control and automation systems.
DIP switches and potentiometer allows customization of settings such as sequencing delays, 12V on/off, and more. Security covers are provided to prevent unauthorized personnel from tampering with DIP switches.
Sequencing of duplex initiated remotely by standard analog triggering (remote terminal) or data link (SmartSequencing from CN-1800S or CN-2400S).
The CN-20MP can shut itself off automatically when triggered by a fire alarm.
SmartSequencing™
SmartSequencing allows bidirectional, safe sequenced power up/down operations via the push of a button or turn of a key.
Voltage Protection
Extreme Voltage Shutdown (EVS) safeguards from catastrophic under-voltage (under 80V sustained) or over-voltage (over 145V sustained) conditions. The EVS feature can be selectively enabled or disabled according to the preference of the user.
BlueBOLT Compatible®
IP Control (Telnet or cloud-based BlueBOLT) via SmartSequencing (when connected to CN-1800S/CN-2400S with BB-RS232 Adaptor).
Diagnostic Lights
Diagnostic lights provide valuable system information including power quality.
20 Amp Output Current
20 amp maximum current capacity.
DIP Switch Customization
DIP switches and potentiometer allows customization of settings such as sequencing delays, 12V on/off, and more. Security covers are provided to prevent unauthorized personnel from tampering with DIP switches.
Specifications
• AC Voltage Input Range 90-139VAC, 50/60Hz
• Maximum AC Current Rating 20 Amps (No Breaker)
• AC Cord 3/12AWG, 10 feet, black, fixed, NEMA 5-20P plug
• AC Receptacles 2 NEMA 5-20R’s (1 duplex)
• Surge/Under-Overvoltage Protection AC Undervoltage Protection: EVS,
77VAC+/-3VAC AC Overvoltage Protection: EVS, 140VAC+/-5VAC AC
Overvoltage Reset Modes: Enabled and disabled (configurable via DIP
Switch #9)
• Operating Temperature Range 5C (40F) to 40C (105F) degrees
• Humidity Range <90% rH (Relative Humidity)
• User Interface: Circuit Breaker: No Breaker Front panel diagnostic
indicators (LED): Power, Extreme Voltage, Primary Link, Secondary Link
Side Panel DIP Switch Features (with security cover): 1 Minute Delay, 2
Minute Delay, 4 Minute Delay, Force Off NO/NC, 12V Mode On/Off GND Mode
On, Momentary/Maintained, Primary/Secondary, EVS Reset Auto/Manual Side
Panel Potentiometer allows fine tune delay adjustments
• Control/Status/Triggering (Rear Panel): Remote Terminal: +5-30VDC In,
12VDC (12mA) Out SmartSequencing: Phoenix-type 4-Pin Connector, Screw
Terminals, Primary & Secondary Links (Current Loop - 1000’ nominal)
Remote Terminal: Phoenix-type 5-Pin Connector With Screw Terminals;
+12V, STAT, REM, GND, DLY_OUT (Class 1 Wiring) Force Off: Phoenix-type
2-Pin Connector With Screw Terminals, FORCE OFF (Class 1 Wiring) RS-232
Compatible: Yes, indirectly, when connected via SmartSequencing to a
Furman Smart Sequencer with an RS-232 port IP Accessibility: Optional IP
control via Telnet, HTTP, or BlueBOLT® when used in conjunction with
SmartSequencing Voltmeter: Available with SmartSequencing Ethernet
option, ± 2VAC accuracy Ammeter: Available with SmartSequencing Ethernet
option, ±1A accuracy
• Power Consumption (No Load): 10 Watts
• Safety Agency: CSA, RoHS Compliant
AC Voltage Input RangeMaximum AC Current RatingAC Cord- 3/12AWG, 10 feet, black, fixed, NEMA 5-20P plug
AC Receptacles- 2 NEMA 5-20R’s (1 duplex)
Surge/Under-Overvoltage Protection- AC Undervoltage Protection: EVS, 77VAC+/-3VAC
- AC Overvoltage Protection: EVS, 140VAC+/-5VAC
- AC Overvoltage Reset Modes: Enabled and disabled (configurable via DIP Switch #9)
Operating Temperature Range- 5C (40F) to 40C (105F) degrees
Humidity Range- <90% rH (Relative Humidity)
User Interface:- Circuit Breaker: No Breaker
- Front panel diagnostic indicators (LED): Power, Extreme Voltage, Primary Link, Secondary Link
- Side Panel DIP Switch Features (with security cover): 1 Minute Delay, 2 Minute Delay, 4 Minute Delay, Force Off NO/NC, 12V Mode On/Off GND Mode On, Momentary/Maintained, Primary/Secondary, EVS Reset Auto/Manual
- Side Panel Potentiometer allows fine tune delay adjustments
Control/Status/Triggering (Rear Panel):- Remote Terminal: +5-30VDC In, 12VDC (12mA) Out
- SmartSequencing: Phoenix-type 4-Pin Connector, Screw Terminals, Primary & Secondary Links (Current Loop - 1000’ nominal)
- Remote Terminal: Phoenix-type 5-Pin Connector With Screw Terminals; +12V, STAT, REM, GND, DLY_OUT (Class 1 Wiring)
- Force Off: Phoenix-type 2-Pin Connector With Screw Terminals, FORCE OFF (Class 1 Wiring)
- IP Accessibility: Optional IP control via Telnet, HTTP, or BlueBOLT® when used in conjunction with SmartSequencing.
- Voltmeter: Available with SmartSequencing Ethernet option, ± 2VAC accuracy
- Ammeter: Available with SmartSequencing Ethernet option, ±1A accuracy
Power Consumption (No Load):Safety Agency:- CSA, RoHS Compliant
- WEIGHT---5.4 LBS
|
|
|